Post Offer Free
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd  

Gold Index: 9232

You are here: home  > EKCC015A 3600W Split Air Conditioning Units 220V 50Hz For Office Buildings

EKCC015A 3600W Split Air Conditioning Units 220V 50Hz For Office Buildings 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: EKCC 010A-015A

EKCC 010A - EKCC 015A low static pressure central duct type air conditioner
<span style="font

EKCC 010A - EKCC 015A low static pressure central duct type air conditioner
 
 
Specifications:

Model Indoor unit EKCC010A EKCC015A
Outdoor unit EKAA010AC   EKAA010ARC   EKAA015AC   EKAA015ARC  
Nominal cooling capacity W                  2600 2600 3600 3600
Nominal heating capacity W -- 2800 -- 3800
Rated input power Cooling W 950 960 1270 1280
Heating W -- 890 -- 1110
Rated current Cooling A 4.5 4.5 6.0 6.0
Heating A -- 4.2 -- 5.2
EER W/W 2.74 2.71 2.83 2.81
Energy Efficiency Rating / / / /
Indoor unit Air flow m3/h 450 580
External static pressure Pa 15(0/30/50)
Indoor unit weight kg 22 22
Noise (high/medium/low) dB(A) 30/28/26 31/29/27
Length x width x height mm 1024×467×210
Outdoor unit Noise dB(A) 52 52
Outdoor unit weight kg 35 40
Length x width x height mm 780×255×538
Power supply 220V~/50Hz
Connector size Liquid pipe external
diameter φmm (in.)
φmm(in.) 6.35(1/4) 6.35(1/4)
Gas pipe external
diameter φmm (in.)
φmm(in.) 9.52(3/8) 12.7(1/2)
Water drainage pipe R3/4
Shell of exposed hoisting unit EKCC010E EKCC015E
Shell dimensions
(length x width x height)
mm 1223×557×272

 
Note:
The GB 19576-2004 EER standard is applied.
The nominal cooling capacity is measured under the following conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor dry bulb
reads 35 °C.
The nominal heating capacity is measured under the following conditions: The indoor dry/wet bulb reads 20/15 °C and the outdoor dry/wet
bulb reads 7/6 °C.
The preceding performance data is based on the condition that the connection pipe between indoor and outdoor units is 5 m.
The air amount of the indoor unit is the air amount at high wind speed under standard static pressure.
The value in brackets for static pressure outside the unit is an optional value for static pressure. When an external hot water coil box is
used, the air resistance of the hot water coil box needs to be deducted from the original static pressure outside the unit to obtain the static
pressure value outside the unit.
The noise value for the indoor unit is measured under standard static pressure outside the unit in a semi-anechoic room without air return
plenum. The noise increases by about 5 dB(A) in the case of downward air return.
An indoor unit with an external electric heater box or external hot water coil box is equal to a standard unit.
For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.
 
Description:
 
Indoor Unit


1, The unit features ultra-low operation sound. All parts such as fans and motors are carefully selected and continuously improved. The structure and pipeline also feature professional noise dampening design, significantly reducing the noise level to an industry-leading level (26 dB at low speed).
2. The wire controller features a large-screen LCD with blue backlight, and can automatically detect and precisely control the indoor temperature. Various functions are available to make indoor air comfortable whilesaving energy.
3. Multiple bacteria dampening devices are available (such as bacteria dampening filter, ultraviolet sterilamp, and photocatalyst filter) for cleaning the air and killing harmful bacteria. (The unit must be equipped with a return air plenum to implement this function.)
4. Fresh air is replenished to reduce the density of CO2 indoor and increase the percent of oxygen to avoid air-conditioning syndrome. When the unit is used with EKHR total heat recovery units to replenish fresh air indoor, customers can enjoy comfort while saving energy cost.
5. The unit is available in concealed hoisting and exposed hoisting modes, meeting requirements for indoor decoration
6. The static pressure can be converted onsite to meet different requirements for air supply distance.

 

Model Standard static pressure (Pa) Optional static pr
bigPhoto
 Mr. Mr. Rocky

Tel: 86-769-83660888
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (193)