Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
|
Gold Index: 9232
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
9.7kW Residential Air Conditioners Heat Pump Small Air-cooled Cold/Hot Water Integrated Unit
Specifications:
Technical data sheet
Model | EKAC 040 ARW/N | ||
Nominal cooling capacity | kW | 9.7 | |
×103kcal/h | 8.34 | ||
Nominal heating capacity | kW | 11 | |
×103kcal/h | 9.46 | ||
Total power of nominal cooling capacity | kW | 3.8 | |
Total power of nominal heating capacity | kW | 4.1 | |
Power supply | 220V~/50Hz | ||
Refrigerant | Type | R22 | |
Flow control | Capillary | ||
Water side heat exchanger | Evaporator type | Vacuum braze-welded stainless steel plate heat exchanger | |
Water flow for cooling | m3/h | 1.7 | |
Water flow for heating | m3/h | 1.9 | |
Compressor | Type | Fully hermetic rotary compressor | |
Fan | Type | High-efficiency axial fan | |
Qty. | Set | 2 | |
Water pump | Type | Horizontal centrifugal water pump | |
External lift | m | 12 | |
Volume of water tank | L | 22 | |
Volume of expansion water tank | L | 2 | |
Size of inlet/outlet water pipe connector | Rc1 | ||
Dimensions (L/W/H) | Outdoor unit | mm | 1005x430x1285 |
Indoor unit | mm | 835x810x350 | |
Sound | Outdoor unit | dB(A) | 56 |
Indoor unit | dB(A) | 42 | |
Refrigerant Size of pipe connectors | Liquid pipe | mm | Φ 9.52 |
Gas pipe | mm | Φ 15.88 | |
Power cable specification |
Section area of live line | 2 mm |
4 |
Qty. of live lines | PCS | 1 | |
Section area of null line | 2 mm |
4 | |
Qty. of null lines | PCS | 1 | |
Section area of grounding line | 2 mm |
1 | |
Qty. of grounding lines | PCS | 1 | |
Net weight | Outdoor unit | kg | 142 |
Indoor unit | kg | 56 |
Note:
Working conditions for nominal cooling capacity test: water flow rate 0.172m3/(h.kw); temperature of outlet water 7°C;
outdoor ambient temperature 35°C.
Working conditions for nominal heating capacity test: water flow rate 0.172m3/(h.kw); temperature of outlet water 45°C;
temperature of outdoor dry/wet bulb 7°C/6°C.
The sound level is tested before the unit leaves factory. Practically, due to environment noise and other factors, the sound level
tested might be different from those listed in the above table.
Please refer to the User Manual for specific operation ranges.
Description
1. Units of this series feature a classic European air conditioner design (chilled water/heat pump + indoor terminals) for precise temperature control. The units can provide you with a comfortable, healthy and graceful working/living environment. The uni ts feature a heat sink mechanism using circulatory air and needs no cooling tower. This not only saves the cost of the cooling tower, but also saves precious building space. Units of this series feature various models and dimensions to meet different installation requirements.
2. Units of this series are equipped with fully hermetic compressors which are stable, advanced and reliable. All components have undergone strict integration and compatibility test to ensure optimized performance and efficient/energy-saving operation all year round. The solenoid interlock control function can shut down the master unit and water pump automatically when all fans have stopped working, making the unit more energy saving.
3. Long and strict tests prove that units of this series can work reliably in an environment as hot as 48°C (cooling) or as cold as -10°C (heating). With a smart split design, all water pipes can be installed indoor to prevent freezing during cold winters. The units can work with boilers to meet heating requirements in areas which are extremely cold in winter. The units feature built-in high/low pressure protection, cooling freezing protection, winter freezing protection, compressor overload protection, water pressure-drop switch etc. to maximize reliability. In case of any failure, the micro-computer controller provides alarms using sound and indicators on a real-time basis. Besides unconditional manual defrosting, the controller also supports efficient auto defrosting based on multiple parameters during heating operations.
4. The units feature a strengthened vibration isolation case and multi-grade sound dampening. Thanks to a fully hermetic scroll compressor and a low-rev
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd [China (Mainland)]
Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)