Model No.: EKAC 060BR

15.5kW Residential Air Conditioners Heat Pump Small Air-cooled Cold/Hot Water Integrated Unit
 
<span style

15.5kW Residential Air Conditioners Heat Pump Small Air-cooled Cold/Hot Water Integrated Unit

 

Specifications:

 

Technical data sheet

 

Model EKAC 060B
Nominal cooling capacity kW                              15.5
×103kcal/h 13.33                                                  
Nominal heating capacity kW 17
×103kcal/h

14.62

Total power of nominal cooling capacity kW 5.2
Total power of nominal heating capacity kW 5.3
Power supply 380V/3N~/50Hz
Refrigerant Type                                            R22
Flow control Capillary
Water side heat exchanger Evaporator type Vacuum braze-welded stainless steel plate heat exchanger
Water flow for
cooling
3
m /h
2.7
Water flow for
heating
3
m /h
2.9
Compressor Type Fully hermetic volute compressor
Lubricant Mineral oil (SUNISO 3GS)
Fan Type Horizontal centrifugal water pump
Qty. 2
Water pump Type Horizontal centrifugal water pump
External lift m 12
Size of inlet/outlet water pipe connector Rc1
Dimensions (L/W/H) mm 1010x490x1245
Sound dB(A) 64
Power cable
specification
Section area of live line 2
mm
4
Qty. of live lines PCS 3
Section area of null line 2
mm
4
Qty. of null lines PCS 1
Section area of grounding line 2
mm
4
Qty. of grounding lines PCS 1
Unit weight Net weight kg 220
Operating weight kg 239
Water system Accessory kit Model EKAC-WS08A
Water tank L 38
Expansion water tank L 8
Size of pipe connectors Rc1

 

 

Note:
Working conditions for nominal cooling capacity test: water flow rate 0.172m3/(h.kw); temperature of outlet water 7°C;
outdoor ambient temperature 35°C.
Working conditions for nominal heating capacity test: water flow rate 0.172m3/(h.kw); temperature of outlet water 45°C;
temperature of outdoor dry/wet bulb 7°C/6°C.
The sound level is tested before the unit leaves factory. Practically, due to environment noise and other factors, the sound level tested might
be different from those listed in the above table.
Please refer to the User Manual for specific operation ranges.

 

Description

 

1. Units of this series feature a classic European air conditioner design (chilled water/heat pump + indoor terminals) for precise temperature control. The units can provide you with a comfortable, healthy and graceful working/living environment. The uni ts feature a heat sink mechanism using circulatory air and needs no cooling tower. This not only saves the cost of the cooling tower, but also saves precious building space. Units of this series feature various models and dimensions to meet different installation requirements.

2. Units of this series are equipped with fully hermetic compressors which are stable, advanced and reliable. All components have undergone strict integration and compatibility test to ensure optimized performance and efficient/energy-saving operation all year round. The solenoid interlock control function can shut down the master unit and water pump automatically when all fans have stopped working, making the unit more energy saving.

3. Long and strict tests prove that units of this series can work reliably in an environment as hot as 48°C (cooling) or as cold as -10°C (heating). With a smart split design, all water pipes can be installed indoor to prevent freezing during cold winters. The units can work with boilers to meet heating requirements in areas which are extremely cold in winter. The units feature built-in high/low pressure protection, cooling freezing protection, winter freezing protection, compressor overload protection, water pressure-drop switch etc. to maximize reliability. In case of any failure, the micro-computer controller provides alarms using sound and indicators on a real-time basis. Besides unconditional manual defrosting, the controller also supports efficient auto defrosting based on multiple parameters during heating operations.

4. The units feature a strengthened vibration isolation case and multi-grade sound dampening. Thanks to a fully hermetic scroll compressor and a low-rev high-efficiency heat-sink fan, the operation sound and vibration of the units are brought down to an industry leading level. With an innovative auto silence feature for night time,

5. The split se

bigPhoto
 Mr. Mr. Rocky

Tel: 86-769-83660888
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (193)