Post Offer Free
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd  

Gold Index: 9232

You are here: home  > Universal R22 Split Air Conditioning Units With V - Belt Transmission

Universal R22 Split Air Conditioning Units With V - Belt Transmission 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: EKDB 400A(R)-EKDB 600A(R)

EKDB 400A(R)-EKDB 600A(R) high static pressure duct type air conditioning unit
 
 
Spe

EKDB 400A(R)-EKDB 600A(R) high static pressure duct type air conditioning unit

 

 

Specifications:

 

 

Unit model Indoor unit EKDB 400A EKDB 400AR EKDB 500A EKDB 500AR EKDB 600A EKDB6 00AR
Outdoor unit 4xEKAA 100AB 4xEKAA 100ARB 4xEKAA 125AB 4xEKAA 125ARB 4xEKAA 150AB 4xEKAA 150ARB
Nominal cooling capacity W 100000 100000 120000 120000 158000 158000
Nominal heating capacity W -- 115000 -- 130000 -- 183000
Indoor unit Air flow m3/h 20400 20400 25500 25500 30600 30600
External static pressure Pa 200 200 250 250 500 500
Fan drive mode V-belt transmission
Width x depth x height mm 2174x1466x1546 2174x1466x1546 2174x1905x1978
Weight kg 330 330 350 350 999 999
Outdoor unit Compressor model Fully hermetic volute
Width x depth x height mm 4x990x840x1840 4x990x840x1840 4x1290x840x1840
Weight kg 4x265 4x280 4x270 4x285 4x285 4x300
Power supply 380V/3N~/50Hz
Rated input power of integrated unit Cooling W 39500 40500 49000 49500 64700 65200
Heating W -- 36100 -- 43700 -- 60000
Rated current of integrated unit Cooling A 91 91 95 95 120 120
Heating A -- 88 -- 93 -- 114
Refrigerant Type R22
Connection pipe Connect mode Soldering
External diameter of liquid tube mm 4x15.88 4x15.88 4x15.88
External diameter of air tube mm 4x28.6 4x28.6 4x34.9
Condensed water drainage
pipe
R1
External electric heater box Model ACDB-EH6, ACDB-EH8, ACDB-EH10, ACDB-EH12.5, ACDB-EH15, ACDB-EH20, ACDB-EH25, ACDB-EH30, ACDB-EH38, ACDB-EH45, ACDB-EH55
Description You can select an external electric heater box according to the required heating capacity. For specifications
of external electric heater boxes, see P22.

 

Note:
The rated cooling capacity is measured in the following condition: The indoor air dry bulb reads 27°C, the wet bulb reads 19°C, and the
outdoor dry bulb reads 35°C. The condition for the rated heating capacity is as follows: The indoor air dry bulb reads 20°C, the outdoor dry
bulb reads 7°C, and the wet bulb reads 6°C. The cooling capacity and heating capacity change according to the conditions. During model
selection, you need to select a proper model based on local climatic conditions.
External static pressure indicates the static pressure under the nominal air flow. The static pressure may change depending on customer
requirements. For the specific value, see the reading on the nameplate.
The unit input power and current are based on the standard external static pressure. If the customer requires a different external static
pressure, check the nameplate on the unit for the power and current values.
The specifications may suffer change due to product update. The readings on the nameplate of the unit prevail.
The preceding data is based on the condition that the connection pipe between indoor and outdoor units is 7.5m.
For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.
No refrigerant is filled into any unit upon factory delivery.

 

Description:

 

1, Outstanding fans, motors and other components specially designed for air conditioners ensure that the unit operates smoothly.

2, Brand-new dustproof and rustproof painting makes sure that the outdoor unit looks new after many years of operation.

3, The outdoor unit adopts modular design and stepped startup, efficiently reducing shock on the grid.

4, Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost.

5, The compressors support even wear, prolonging the lifecycle

6, Featuring a high static pressure design, the indoor unit can supply conditioned air over a long distance, enabling customers to select the installation site as required. To service any component of the unit, you only need to remove several screws on either side of the unit.

7, The connection pipe between indoor and outdoor units reaches up to 50 m, and the height difference can reach 20 m.

8, T

bigPhoto
 Mr. Mr. Rocky

Tel: 86-769-83660888
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Dongguan
Province/State: Guangdong
Country/Region: China (Mainland)

You May Like:

Product (193)