EKMC Rack-based Modular Rack Cooling (MRC) Closest to Heat Source
Description:
EUROKLIMAT, your trustworthy expert in precision
cooling systems for equipment room!
As various services related to network increase, the loss caused by each service interruption becomes greater and greater. We need to spend more energy and support on infrastructure. The environmental basis for safe and reliable operation of various equipment attracts more and more attention.
Founded in 1963, EUROKLIMAT is the earliest supplier that was engaged in R&D of precision airconditioning
systems for equipment room and provides system solution service. Based on the European leading R&D and design platform, EUROKLIMAT integrates more than 40 years of R&D experience in Europe and excellent engineering design philosophy and provides a wide variety of users with the most
advanced and most reliable precision air-conditioning products used in equipment room. EUROKLIMAT has become a professional leader in the field.
The equipment room precision air-conditioners produced by EUROKLIMAT have successfully served world well-known brands and institutions such as Nokia, Allianz Insurance, DHL, and European aerospace industry. EK China comprehensively introduces European leading product design, R&D and manufacturing and provides products of the same quality to Chinese customers. It can provide users of key environments such as mobile program-controlled switching equipment room and data computing equipment room with the optimum air-conditioning solutions.
Features of the Unit
Provide matching cooling closest to heat source
to reduce energy consumption
The Rack Hot Air Containment (RHAC) is adopted to directly absorb heat from the heat source. By using the hot exhaust air temperature of the server, the cooling capability is maximized. In addition, real-time monitoring is supported. Thermal isolation with RHAC also reduces the cost because no extra hardware is needed for sealing the hot aisle. Rack-based cooling close to the heat source shortens the supply & return air paths and reduces power consumption of the EC fans. At higher exhaust temperature of the server, EKMC cooling output increases with reduced operation cost. Mixing of cold air and hot air is completely eliminated resulting in highest cooling effectiveness. The cold air flows directly to the server inlet to avoid energy offset due to mixing of cold and hot air flow.
Intelligent Control System
The industrial standard microcomputer control center provides the rack-based cooling unit with monitoring, data recording, safety protection and parameter setting. The operation is simple and
information is clear. Chinese and English menus can be selected. RS485 (BMS interface) and SNMP network interface are used as standard options.
Modular design, saving investment
RHAC & the horizontal air flow ensures cold air is supplied directly to the inlet of the servers without additional hardware for cold or hot aisle containment as needed for traditional configurations and raised floor is not required
Applications:
Data center |
service room,computer room, The bank, securities and insurance company, communication center |
Financial organizations |
Banks, negotiable securities, funds, insurance companies, pawnshops;non-profit Organizations: Telecommunications, post offices, hospital, schools |
Specifications:
Model | EKMC30 | |
Nos. of Fan | No. | 2 |
Rated Air Volume (80% Speed) | m3/h | 4,350 |
Sound Level | dB(A) | 67 |
Max Air Volume (Full Speed) | m3/h | 5,450 |
Power Supply | V/Ph/Hz | 220/1/50 |
Max Current | A | 3.52 |
Max Power Input | kW | 0.733 |
Power Input( Full Speed) | kW | 0.733 |
Power Input( 80% Speed) | kW | 0.388 |
Total Capacity (80% Speed) | kW | 27.3 |
Total Capacity (Full Speed) | kW | 31.2 |
Nos. of DX Coil Rows | No. | 3 |
Material of Coil | Copper pipe with aluminum fin | |
Refrigerant | R407C/R410A | |
Liquid/Gas Piping Size | mm | 12.7/ 22.23 |
Condensate Water Pump Piping Size(Optional) | ||
Unit Gross Weight | kg | 80 |
Unit Weight | kg | 65 |
Unit Operating Weight | kg | 69 |
Unit Dimension (H x W x D) |
Related Search
Conditioning Unit
Air Conditioning
Car Air Conditioning
Automotive Air Conditioning
Auto Air Conditioning
Automobile Air Conditioning
More>>
Find more related products in following catalogs on Hisupplier.comRelated ProductsCompany InfoGuangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd [China (Mainland)]
Business Type:Manufacturer You May Like:
Printable Page
Bookmark this page
Sitemap XML About HiSupplier Help Center Customer Service Friend Links Site Map Archives Browse by: China Suppliers - Hot Products - Products Directory - Offers Directory - Suppliers Directory - Buyers Directory Language Option: العربية - Nederlands- Français- Deutsch- Italiano- 日本語- 한국의- Português- Pусский- Español Copyright © HiSupplier.com Online Inc. All Rights Reserved.
|